Load-Bearing Element: Typically a high-tensile steel core or reinforced aluminum strand, this component bears the mechanical stress of overhead installation. In models like SIP-5ng, the load-bearing element is engineered to support spans up to 50 meters, eliminating the need for intermediate poles and reducing infrastructure costs. The steel core in SIP-4 and Sipn-4 provides a tensile strength of 18kN, ensuring stability even in wind speeds up to 120km/h—equivalent to a Category 1 typhoon.
Conductive Conductors: These are the current-carrying elements, constructed from high-purity aluminum or copper. Aluminum is favored for its balance of conductivity and lightweight properties, while copper options (available in select models like Asxsn) offer superior conductivity for high-precision applications. The 4X50 configuration in SIP-5ng features four 50mm² conductors, each capable of carrying 125A, enabling a total current capacity of 500A for three-phase systems.
Insulation Sheath: A durable layer—usually XLPE or PVC—encases the conductors, providing electrical isolation and environmental protection. XLPE-insulated models (e.g., SIP-5) withstand operating temperatures up to 90°C, while PVC variants (common in SIP-1 and Sipn-1) offer cost-effective protection in moderate climates. The insulation is extruded in a continuous process, ensuring uniformity and eliminating weak points that could lead to short circuits.
Torsional Stability: The twisted configuration of conductors (in models like SIP-2 and Sipn-2) distributes tension evenly, preventing sagging and maintaining consistent clearance from the ground. This stability is critical for compliance with safety standards, which require a minimum clearance of 3.5 meters over pedestrian areas.
Fatigue Resistance: The load-bearing element is treated with anti-fatigue coatings to withstand cyclic stresses. For example, SIP-4 wires undergo 10,000 cycles of tension testing (from 20% to 80% of breaking strength) without degradation, ensuring a service life of 25+ years in urban environments.
Flexibility: Despite their structural strength, these wires retain sufficient flexibility for installation. The minimum bending radius for SIP-1 is 12 times the outer diameter (typically 150mm), allowing easy routing around obstacles like buildings or trees.
4X50 Configuration: Four 50mm² conductors deliver exceptional current capacity, making them ideal for industrial complexes, large commercial centers, and power distribution substations. The 50mm² cross-section minimizes resistance (0.588Ω/km), reducing energy loss by up to 15% compared to smaller gauges.
4X35 Configuration: A more compact variant, suitable for medium-load scenarios like multi-story residential buildings and regional distribution lines. The 35mm² conductors balance capacity (95A per conductor) with material efficiency, reducing overall weight by 20% compared to 4X50 while maintaining sufficient power handling.
Enhanced Core: SIP-5ng features a galvanized steel core with a tensile strength of 22kN, enabling spans up to 50 meters. This makes it particularly valuable for rural electrification projects where minimizing pole density reduces environmental impact and costs.
SIP-1 and Sipn-1: Designed for residential neighborhoods, these wires typically feature 2-3 conductors (16mm² or 25mm²) with a PVC Insulation rated for 60°C. Their lightweight design (1.2kg/m) simplifies manual installation, making them popular for small-scale projects in provinces like Bohol or Palawan.
SIP-2 and Sipn-2: Catering to small commercial establishments (e.g., sari-sari stores, offices), these wires offer 3-4 Conductors (25mm² or 35mm²) with XLPE insulation. The XLPE allows continuous operation at 90°C, accommodating occasional overloads from air conditioning units or commercial equipment.
Key Difference: Sipn-1 and Sipn-2 include a neutral conductor with enhanced insulation, providing additional protection against voltage fluctuations—a critical feature in areas with unstable grid supply.
SIP-4 and Sipn-4: Equipped with 4 conductors (35mm² or 50mm²), these wires handle the mixed loads of urban areas—from residential blocks to shopping districts. Their reinforced insulation resists abrasion from tree branches and debris, reducing maintenance in densely vegetated areas like Quezon City.
SIP-5: A high-performance variant with a hybrid insulation system (XLPE core + PVC outer layer) that combines thermal resistance with UV protection. This makes it suitable for exposed installations in cities with high sunlight exposure, such as Manila or Cebu.
Smart Grid Compatibility: SIP-5 includes an auxiliary 10mm² conductor for communication signals, enabling integration with SCADA systems for remote monitoring—essential for modern smart grids.
Asxs: Designed for high-moisture environments (e.g., coastal areas, wetlands), Asxs features a triple-layer insulation system (PE + XLPE + PE) that provides 100% water resistance. Testing shows no degradation after 1,000 hours of immersion in saltwater, making it ideal for projects in Palawan or Leyte.
Asxsn: Built for chemical exposure (e.g., industrial zones, agricultural areas with pesticide use), Asxsn uses a chemical-resistant EPDM (Ethylene Propylene Diene Monomer) insulation. It withstands exposure to common chemicals like sulfuric acid (10% concentration) and ammonia, ensuring reliability in factories or farmland.
Copper Conductors: Asxsn offers optional Copper Conductors for applications requiring minimal signal interference, such as Power Lines near communication towers.
XLPE (Cross-Linked Polyethylene): Used in SIP-5, SIP-4, and SIP-5ng, XLPE undergoes a cross-linking process that enhances thermal stability and dielectric strength. It operates at temperatures up to 90°C, resists water treeing (a common cause of insulation failure in humid climates), and has a dielectric strength of 20kV/mm—suitable for 11kV to 33kV networks.
PVC (Polyvinyl Chloride): Found in SIP-1, Sipn-1, and budget variants, PVC offers cost-effective protection in moderate conditions. It has a maximum operating temperature of 70°C and provides good UV resistance, though it is less flexible than XLPE in cold weather (below 0°C).
EPDM (Ethylene Propylene Diene Monomer): Exclusive to Asxsn, EPDM is a synthetic rubber with exceptional chemical and weather resistance. It remains flexible at -40°C and stable at 120°C, making it suitable for extreme temperature fluctuations.
PE (Polyethylene): Used as a secondary layer in Asxs, PE adds moisture resistance and flexibility. Its low dielectric constant (2.3) minimizes signal loss, making it ideal for wires with integrated communication conductors.
Conductivity: Aluminum Conductors in SIP-5ng achieve 61% IACS (International Annealed Copper Standard), while copper conductors in Asxsn reach 98% IACS—ensuring efficient power transfer with minimal loss.
Voltage Rating: Models are rated for 0.6/1kV (residential), 11kV (urban distribution), and up to 33kV (industrial). SIP-5ng 4X50 is certified for 33kV applications, making it suitable for substation connections.
Short-Circuit Withstand: All models withstand short-circuit currents for 1 second: SIP-5ng handles 25kA, SIP-4 handles 20kA, and SIP-1 handles 10kA—protecting equipment during fault conditions.
Temperature Range: -40°C to 90°C for XLPE models; -20°C to 70°C for PVC models; -40°C to 120°C for EPDM models (Asxsn).
UV Resistance: PVC and XLPE insulation includes UV stabilizers, ensuring 90% retention of tensile strength after 3,000 hours of accelerated UV testing—equivalent to 20 years of outdoor exposure.
Chemical Resistance: Asxsn resists 5% sulfuric acid, 10% ammonia, and motor oil, with less than 10% weight loss after 1,000 hours of immersion.
IEC 60502: All models meet this international standard for Power Cables, ensuring compatibility with global electrical systems.
ASTM D2225: XLPE insulation complies with this standard for cross-linked polyethylene, verifying thermal and dielectric performance.
Philippine Electrical Code (PEC): Certified for use in the Philippines, adhering to local safety requirements for overhead lines (Chapter 230).
Storage: Store wires in dry, covered areas to prevent moisture absorption. PVC-insulated models should avoid direct sunlight to prevent premature aging.
Inspection: Before installation, check for insulation cracks, conductor damage, or kinks. Pay special attention to the load-bearing element—any signs of corrosion (e.g., rust on steel cores) require replacement.
Tensioning: Use calibrated tensioners to apply the correct tension: 10kN for SIP-5ng (50m spans), 8kN for SIP-4 (40m spans), and 5kN for SIP-1 (30m spans). Over-tensioning can damage insulation; under-tensioning causes sagging.
Clearing Obstacles: Maintain minimum clearances: 3.5m over sidewalks, 5m over roads, and 0.6m from buildings. Use insulated brackets for wall-mounted installations.
Termination: Use manufacturer-approved lugs and connectors. For Aluminum Conductors, apply anti-oxidant paste to prevent corrosion at connection points.
Insulation Resistance: Test with a 5kV megohmmeter—values should exceed 1000MΩ for new installations.
Tension Verification: Recheck tension after 24 hours to account for initial creep, especially in longer spans.
Suburban Neighborhoods: SIP-1 and Sipn-1 connect 50-100 homes per line, with 25mm² conductors handling typical household loads (air conditioners, refrigerators, lighting).
Apartment Complexes: SIP-4 4X35 wires supply multi-story buildings, supporting 20-30 units with a combined load of 400A.
Retail Centers: SIP-5ng 4X50 powers malls and supermarkets, handling peak loads from escalators, freezers, and lighting systems.
Factories: SIP-5ng 4X50 connects industrial facilities, supporting machinery with 33kV requirements and high current draws.
Airports and Seaports: Asxsn wires are used in these environments due to resistance to jet fuel, saltwater, and heavy machinery vibrations.
Renewable Energy: SIP-4 connects solar farms to distribution grids, with XLPE insulation handling temperature fluctuations from day-night cycles.
Coastal Areas: Asxs wires resist saltwater corrosion, making them ideal for beach resorts and coastal towns like Boracay.
Chemical Plants: Asxsn’s EPDM insulation withstands industrial chemicals, used in facilities near Batangas and Laguna.
Mountainous Regions: SIP-5ng’s long-span capability reduces pole requirements in rugged terrain, such as the Cordillera Administrative Region.
Inspection Schedule: Quarterly visual checks in industrial areas; semi-annual checks in residential areas. Look for insulation damage, bird nests, or vegetation contact.
Cleaning: Annually clean with a soft brush and mild detergent to remove dirt and pollutants. High-pressure washing is not recommended for PVC insulation.
Repair: Small insulation damage can be repaired with heat-shrink sleeves. Replace sections with conductor damage or excessive sagging.
Lifespan: 25-30 years for XLPE models; 15-20 years for PVC models; 30+ years for Asxsn (EPDM) in moderate conditions.
Initial Costs: Prices range from PHP 80/m (SIP-1 PVC) to PHP 350/m (Asxsn copper). The self-supporting design reduces installation labor costs by 30-40% compared to traditional lines with messenger cables.
Lifecycle Costs: Lower maintenance requirements (annual cost of PHP 5/m vs. PHP 12/m for traditional lines) and reduced energy loss (saving PHP 0.02/kWh) result in a typical payback period of 3-5 years.
Total Cost of Ownership: Over 20 years, SIP-5ng 4X50 costs 25% less than equivalent traditional lines when factoring in installation, maintenance, and energy savings.
Hongtai Cable Technology Co., Ltd
E-mail: export@qlcables.com
sales@qlcables.com
Tel/whatsapp:+86-18032066271
Tambahkan : Zona Pengembangan Industri Xiaokou, Kabupaten Ningjin, Kota Xingtai , Provinsi Hebei, Cina
Hak Cipta © Hongtai Cable Technology Co., Ltd Dukungan Teknis:Teknologi Ronglida
Situs web ini menggunakan cookie untuk memastikan Anda mendapatkan pengalaman terbaik di situs web kami.