Pusat Produk
Rumah > Pusat Produk > Kabel tegangan rendah > Power Cable Yaxv Multi-Core with Insulated Ground Conductor Na2xy 3X150 Sm

    Power Cable Yaxv Multi-Core with Insulated Ground Conductor Na2xy 3X150 Sm

  • Klasifikasi mereka:
    Kabel tegangan rendah
  • membagikan:
  • Kode QR:
  • Waktu rilis:
    2025-07-24 09:11:50
  • Pertanyaan Instan

I. Information Related to the Product Itself

(I) Specification Parameters
Power Cable Yaxv Multi - Core Cable (Na2xy 3×150 Sm) has rigorous settings in terms of specification parameters. Each parameter is carefully considered to ensure its stable performance in power transmission.
The core specification of this cable is 3×150mm², which means it contains 3 cores with a cross - sectional area of 150mm² and can carry a large current. Under standard working conditions, its continuous current - carrying capacity can reach about 300A, which can fully meet the needs of medium and high - power power transmission and is suitable for various scenarios requiring high power supply.
Its rated voltage is 0.6/1kV, which conforms to the general standard of low - voltage power distribution systems. Among them, 0.6kV is the phase voltage and 1kV is the line voltage. It can be perfectly compatible with common low - voltage power distribution equipment, ensuring that there will be no faults due to voltage mismatch during power transmission and laying a foundation for the stability of power transmission.
The insulated ground conductor is an important part of the cable, and its insulation performance meets relevant standards. The insulation resistance is not less than 1000MΩ·km at room temperature, which can effectively prevent current leakage and ensure the safety and reliability of the grounding function. At the same time, the cross - sectional area of the ground conductor is compatible with the main core, ensuring that when there is a leakage, the current can be quickly introduced into the ground to avoid safety accidents.
In addition, the bending radius of the cable is 12 times the outer diameter of the cable, which can adapt to a certain degree of bending and laying needs, and can be installed normally in some laying environments with limited space or needing to turn. It has a wide operating temperature range and can maintain stable performance between - 40℃ and 70℃, and can adapt to different climate and environmental conditions.

(II) Characteristic Uses
Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) has a wide range of targeted applications in many fields relying on its own performance advantages, and can meet the power transmission needs in different scenarios.
It is an ideal choice in the field of industrial power distribution. In the production workshops of factories, there are many large - scale production equipment, such as large - scale CNC machine tools and punch presses. These equipment need stable high - power power supply. The 3×150mm² specification of the cable can provide sufficient current - carrying capacity to ensure the normal operation of the equipment. At the same time, the insulated ground conductor can effectively prevent equipment leakage and provide guarantee for the production safety of the workshop. In the main line from the factory's substation to the workshop's main distribution box, the cable can also play an important role in ensuring that power is stably transmitted from the substation to each workshop.
The cable is also competent in the power distribution system of large - scale buildings. For large - scale buildings such as shopping malls and office buildings, the total power consumption of internal air conditioning systems, elevators, lighting and other equipment is large. Cables with 3×150mm² specification can be used as the main power distribution lines of the building, connecting from the main distribution box of the building to the distribution boxes of each floor, and providing support for the power supply of the entire building. In these places with dense personnel, the existence of insulated ground conductors can greatly reduce the risk of leakage and ensure personnel safety.
In the field of public facilities, the cable also has application space. For example, large - scale public venues such as gymnasiums and exhibition halls need a large number of temporary electrical equipment, such as stage lighting and sound, when holding activities. The cable can be used as the main line of temporary power supply lines to meet the power demand of high - power equipment. At the same time, its good insulation performance and grounding function can adapt to the complexity of the temporary laying environment.
In addition, the cable can also play a role in new energy - related supporting facilities. For example, in the low - voltage line from the inverter to the booster station of a photovoltaic Power Station, it can be used for power transmission, and its stable current - carrying capacity and safety performance can meet the requirements of photovoltaic power transmission.
(III) Material and Style
The material selection and style design of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) are closely related to its performance and use, providing a strong guarantee for its stable operation and convenient installation.
The core is made of high - purity copper with a purity of more than 99.95%. High - purity copper has excellent conductivity and extremely low resistivity, which can minimize energy loss during power transmission and improve power transmission efficiency. The core adopts a multi - strand stranded structure, which is made of multiple fine Copper Wires stranded together. This structure enhances the Flexibility of the core, enabling it to better adapt to bending paths during laying and reducing the possibility of fracture. At the same time, the stranded structure can also improve the mechanical strength of the core, making it not easy to be damaged when pulled by external forces.
The insulation layer is made of high - quality polyvinyl chloride (PVC) material, which has good insulation performance and chemical corrosion resistance. It can effectively isolate the current conduction between cores and between cores and the external environment, ensuring the safety of power transmission. The PVC Insulation layer has good temperature resistance. It can maintain stable performance below 70℃ without softening, deformation and other situations, and is suitable for general use environments.
The insulation layer of the insulated ground conductor is also made of PVC material, and after special treatment, its insulation performance is more reliable. The surface of the ground conductor has a clear logo, which is convenient for installation and maintenance personnel to identify and avoid wiring errors.
In terms of style, the cable has a multi - core cabling structure and is round as a whole. The multi - core structure can meet the needs of three - phase power supply. The round structure enables the cable to bear uniform force during laying, and is convenient to match with laying facilities such as pipes and cable trays. The outer sheath of the cable is made of black PVC material with a smooth surface, and is printed with clear marks, including model, specification, rated voltage, manufacturer and other information, which is convenient for identification and traceability.
(IV) Production Process
The production process of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) is rigorous and standardized. Each link from raw material processing to finished product inspection has strict quality control to ensure that the product meets relevant standards and design requirements.
Core stranding is the first step of production. High - purity copper rods are drawn into fine copper wires with uniform diameter through a wire drawing process. During the wire drawing process, the wire drawing speed and die precision are strictly controlled to ensure that the surface of the copper wires is smooth and free of burrs. Then, according to the specification requirements of 150mm², a certain number of fine copper wires are stranded by a stranding machine. During stranding, stable tension and appropriate pitch are maintained to make the Stranded Core have a compact and round structure, and at the same time ensure the flexibility of the core. After stranding, annealing treatment is carried out to eliminate the internal stress generated during the stranding process and further improve the conductivity and flexibility of the core.
The insulation extrusion link is crucial. First, the PVC Insulation Material is dried to remove moisture from the material to avoid bubbles in the insulation layer. The dried PVC material is sent to the extruder, melted at a set temperature (usually 160 - 180℃), and evenly coated on the outside of the core through a special extrusion die to form an insulation layer. During the extrusion process, the extrusion speed, temperature and pressure are accurately controlled to ensure that the thickness of the insulation layer is uniform (the deviation does not exceed ±0.1mm), the concentricity with the core is high (the eccentricity does not exceed 10%), and the surface is smooth and free of defects.
The cabling process is to strand 3 Insulated Cores and insulated ground conductors together according to a certain stranding pitch. Filling materials are placed during stranding to make the cabled cable round. At the same time, stable tension is maintained during the stranding process to prevent the cores from loosening. The filling material is a non - hygroscopic material, which can prevent water from entering the cable and ensure the insulation performance of the cable.
Outer sheath extrusion is the last key process. The PVC Sheath material is sent to the extruder, melted at a suitable temperature, and evenly coated on the outside of the cabled core through an extrusion die to form an outer sheath. During the extrusion process, the process parameters are controlled to ensure that the sheath has a uniform thickness, a smooth surface and is closely combined with the internal core. The sheath can protect the internal core from external mechanical damage, moisture, corrosion and other influences.
In the finished product inspection link, a comprehensive test is carried out on the conductivity, insulation performance and mechanical performance of the cable. The conductivity of the core is checked through a DC resistance test, the insulation effect of the insulation layer is verified through insulation resistance and voltage withstand tests, and the mechanical strength of the sheath is inspected through a tensile test. Only cables with all indicators qualified can leave the factory.

II. General Product Information

(I) Packaging
The packaging design of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) focuses on protecting the integrity of the cable during storage, transportation and handling, and at the same time takes into account the convenience of packaging and the clarity of identification.
For coiled cables, wooden cable reels are used for packaging. The diameter of the cable reel is 1.5 - 2 meters, which can stably bear the weight of the cable. The cable is neatly wound on the cable reel, and appropriate tension is maintained during winding to make the cable arranged closely without looseness or distortion, avoiding surface damage caused by mutual friction. Both sides of the cable reel are equipped with baffles, and the height of the baffles is higher than the winding height of the cable to prevent the cable from slipping during transportation and storage.
The outside of the cable reel is wrapped with a layer of plastic film to play a role in moisture - proof and dust - proof. For cables that need long - distance transportation or storage in a humid environment, a layer of waterproof canvas is covered outside the plastic film to further enhance the moisture - proof and sun - proof performance.
A detailed label is pasted on the baffle of the cable reel. The label is marked with product name, model, specification (3×150mm²), length, production batch number, production date, rated voltage, implementation standard, manufacturer name and contact information. The label is made of wear - resistant and waterproof material to ensure that the information is clearly identifiable during transportation and storage. At the same time, warning signs such as "Handle with Care", "Moisture - proof", "Sun - proof" and "Do Not Press Heavily" are also marked on the label.
For small batches or short sections of cable samples, solid cartons are used for packaging. Foam liners are placed inside the cartons to fix the cables in the foam liners to prevent shaking and collision during transportation. Relevant product information and warning signs are also marked on the outside of the cartons.
(II) Transportation
The transportation of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) must follow strict specifications to ensure that the cable is not damaged during transportation and its performance is not affected.
The transportation method is selected according to the transportation distance and quantity. For long - distance transportation with a large quantity, railway transportation or road freight is preferred. Railway transportation has good stability and can reduce jolting during transportation. The cable reels are fixed in the freight carriage, and steel wire ropes or special fastening belts are used to firmly connect the cable reels to the carriage to prevent sliding. For road freight, trucks in good condition with sufficient carrying capacity are selected. The carriage must be flat, clean and free of sharp debris. An appropriate gap is left between the cable reels, and they are separated by buffer materials to prevent mutual collision.
Short - distance transportation can use small trucks or logistics vehicles. Special hoisting equipment is required when loading and unloading cables. The hoisting point should be selected at the central axis of the cable reel. Hoisting from the side of the cable reel or the cable itself is strictly prohibited to prevent deformation of the cable reel or damage to the cable. Handle with care during loading and unloading to avoid violent collision.
The following matters should be noted during transportation: Cables should avoid open - air transportation. If it is unavoidable, they must be covered with waterproof canvas to prevent exposure to the sun and rain; keep away from fire sources, heat sources and corrosive substances. Transport vehicles are not allowed to approach open fire areas and are not mixed with corrosive goods such as acids and alkalis; during transportation, drivers should drive steadily, avoid violent operations such as sudden braking and sharp turns, and reduce the shaking of the cable reels; regularly check the fixing of the cable reels and reinforce them in time if they are loose.
After arriving at the destination, the receiver shall check the packaging and appearance of the cable together with the transporter, and sign for it only after confirming that there is no damage. If there is packaging damage, cable appearance damage and other situations, photos should be taken and recorded in time, and communicate with the shipper and transporter for handling.
(III) Delivery
The delivery process of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) focuses on efficiency and accuracy. There are clear operating specifications for each link from order receipt to goods delivery to ensure that customers can receive qualified products on time.
After the customer places an order, the sales department promptly enters the order information into the system and transmits it to the warehouse and production department. After receiving the order, the warehouse immediately checks the inventory quantity, specifications and other information to ensure that they are consistent with the order. If there is stock, arrange for goods preparation; if it is a customized order, the production department organizes production according to the order requirements, and the production progress is timely fed back to the sales department and customers.
In the goods preparation stage, warehouse personnel conduct strict outgoing inspection on the cables. Check whether the appearance of the cable is intact, whether the label information is consistent with the order, and whether the packaging meets the requirements. At the same time, sort out the product's certificate, test report and other quality certification documents, and prepare them for delivery together with the cable.
Before delivery, the logistics department selects an appropriate transportation method and transportation company according to the order information and customer requirements, signs a transportation contract, and clarifies matters such as transportation time, transportation route and cargo insurance. For urgent orders, priority is given to arranging delivery, and transportation resources are coordinated to ensure delivery within the time required by the customer.
After the goods are delivered, the logistics department promptly feeds back the delivery information (such as the name of the transportation company, waybill number, estimated arrival time, etc.) to the customer to facilitate the customer to track the dynamics of the goods. At the same time, the quality certification documents are sent to the customer by express or electronic document. The warehouse retains delivery records, including delivery orders, transportation contracts, etc., for future reference.
If abnormal situations such as insufficient inventory and transportation delays occur during the delivery process, communicate with the customer in a timely manner, explain the situation and negotiate solutions to protect the customer's right to know and rights.
(IV) Samples
To help customers understand the performance and quality of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) before formal procurement, the company provides sample services. The specifications, materials and performance of the samples are completely consistent with those of mass - produced products.
Customers can apply for samples through sales personnel, the company's official website, customer service hotlines and other channels. When applying, they need to provide information such as the specification, quantity (usually 1 - 5 meters), purpose and contact information of the required samples. Sample applications from customers with clear purchase intentions will be processed first.
Samples are prepared in strict accordance with mass production processes and standards. Special tools are used when cutting cables to ensure flat cuts without burrs. The two ends of the samples are sealed to prevent moisture and impurities from entering. Samples are packaged in small sealed bags or small cable reels. The packaging is marked with sample name, specification, production batch number and other information, and is accompanied by sample descriptions and simple quality test reports.
In terms of sample fees, for potential major customers or those with clear procurement plans, samples can be provided free of charge, with only express fees charged. For general consulting customers, a small sample fee (covering material and processing costs) is charged. If a purchase is made later, the sample fee can be deducted from the payment.
Samples are usually shipped within 3 - 5 working days after receiving the application, and a suitable express method is chosen based on the customer's location. After the samples are shipped, the express waybill number is promptly informed to the customer, allowing them to track the logistics information. After customers receive the samples, if they have any questions about the samples, technical personnel can provide professional consulting services.
(V) After - sales Service
The after - sales service system of Power Cable Yaxv Multi - core Cable (Na2xy 3×150 Sm) is well - established, committed to providing customers with comprehensive support, solving problems encountered by customers during product use, and safeguarding their legitimate rights and interests.
The warranty period of this cable is 18 months from the date of delivery. During the warranty period, if the cable has faults caused by its own quality issues (such as insulation layer breakdown, core breakage, sheath cracking and other faults not caused by human factors), customers can apply for free repair or replacement with the purchase certificate and quality certification documents.
After a customer submits an after - sales application, the after - sales department will respond within 24 hours and arrange technical personnel to communicate with the customer to understand the fault situation. Technical personnel make a preliminary judgment based on the customer's description. For simple problems, they guide the customer to check and handle them through phone calls or videos. If on - site handling is required, technical personnel will be arranged to arrive at the site within 48 hours (except for special areas).
During on - site service, technical personnel conduct a comprehensive inspection of the cable to determine the cause of the fault. If it is indeed a quality problem, they will replace


Pelajari lebih lanjut tentang produk kabel
Hubungi Hongtai Cable Technology Co., Ltd
Hubungi kami

Hongtai Cable Technology Co., Ltd

E-mail: export@qlcables.com

           sales@qlcables.com

Tel/whatsapp:+86-18032066271

Tambahkan : Zona Pengembangan Industri Xiaokou, Kabupaten Ningjin, Kota Xingtai , Provinsi Hebei, Cina

Hak Cipta © Hongtai Cable Technology Co., Ltd  Dukungan Teknis:Teknologi Ronglida


Peta situs

Situs web ini menggunakan cookie untuk memastikan Anda mendapatkan pengalaman terbaik di situs web kami.

Menerima menolak