Basic Specification Description
Safety and Performance Parameters
|
|
Core Material Composition
Conductor: High - purity electrolytic copper (copper content ≥99.95%) is used, which has excellent conductivity (conductivity ≥58MS/m). The conductor has a single - core structure and is stranded with an appropriate number of strands and wire diameters. While ensuring conduction efficiency, it has a certain degree of Flexibility, which is convenient for laying and installation.
Insulation Layer: Cross - linked polyethylene (XLPE) material is used, and the insulation thickness is accurately designed (the specific value is determined according to the specification). XLPE material has excellent heat resistance, with a long - term operating temperature of up to 90℃ and a short - term overload temperature of up to 130℃, which can adapt to power transmission in higher temperature environments. At the same time, it has excellent insulation performance and stable dielectric constant, which can effectively insulate current.
Sheath: Low smoke zero halogen (LSZH) material is used, and the sheath thickness meets relevant standards. LSZH material does not contain halogen, releases low smoke when burned, and does not release toxic gases, so it has extremely high safety. At the same time, it has good wear resistance and chemical corrosion resistance, and can provide reliable protection for the internal structure of the cable.
Structural Advantages
|
|
Core Application Fields
Industrial equipment power supply: Provide power connection for small and medium - sized industrial machine tools, production line motors, pumps and other equipment. Its stable conductivity and heat resistance can meet the power needs of industrial equipment for continuous operation.
Building power distribution trunk lines: Used as power distribution trunk lines in office buildings, shopping malls, residences and other buildings to transmit power from the power distribution room to the distribution boxes on each floor, which is suitable for the medium and low - voltage power distribution systems in buildings.
Public facility power supply: Used for power distribution lines in crowded places such as hospitals, schools and gymnasiums. Because of the LSZH sheath, it can reduce the generation of smoke and toxic gases in case of fire and other accidents, and gain time for personnel evacuation.
New energy - related scenarios: It can be used for low - voltage power distribution lines of small photovoltaic Power Stations and energy storage equipment, adapting to the requirements of the new energy field for cable safety and environmental protection.
Advantages of Scene Adaptation
Key Production Processes
Conductor Preparation: High - purity electrolytic copper rods are drawn and annealed to make Copper Wires with the required wire diameter, and then stranded into conductors according to the designed number of strands. During the stranding process, the conductor structure is ensured to be tight and round.
XLPE Insulation Extrusion: Special extrusion equipment is used to heat and melt the XLPE material, and then uniformly extrude and coat it on the outer layer of the conductor. During the extrusion process, parameters such as temperature and speed are strictly controlled to ensure that the insulation layer has a uniform thickness, a smooth surface and is closely combined with the conductor.
Cross - Linking Treatment: The cable coated with the XLPE insulation layer is cross - linked. Through specific temperature and pressure conditions, the molecular structure of XLPE undergoes a cross - linking reaction to improve its heat resistance and mechanical properties.
LSZH Sheath Extrusion: Extrusion equipment is used to melt the LSZH material and coat it on the cross - linked insulation layer. The extrusion parameters are controlled to ensure that the sheath has a uniform thickness and is well attached to the insulation layer.
Cooling and Forming: The cable with the extruded sheath is cooled and shaped in a cooling water tank to ensure the stable structure of the sheath.
Quality Inspection Standards
Conductor Inspection: Detect the diameter, roundness and DC resistance of the conductor to ensure that it meets the design requirements.
Insulation Layer Inspection: Measure the thickness of the insulation layer, check whether there are defects such as bubbles and cracks on the surface, and test the insulation resistance and voltage resistance performance.
Sheath Inspection: Check the thickness and surface quality of the sheath, test its wear resistance, aging resistance, as well as the smoke generation and toxic gas release during combustion.
Overall Performance Inspection: Conduct overall voltage withstand tests and partial discharge tests on the cable to ensure that its electrical performance meets the standards.
Packaging Form
Protection Design
Transportation Specifications
Road Transportation: Use a suitable truck for transportation. Place the cable reel stably in the carriage and fix it firmly with steel wire ropes to prevent the cable reel from rolling or shaking during transportation. Place buffer pads between cable reels and between cable reels and the carriage to avoid mutual collision damage. Avoid rain, exposure to the sun, etc. during transportation.
Railway Transportation: Load according to relevant railway transportation regulations to ensure that the cable reel is fixed reliably and meets the safety requirements of railway transportation.
Loading and Unloading Requirements: When loading and unloading the cable reel, use special lifting equipment to lift from the lifting hole in the center of the cable reel to avoid deformation of the cable reel or damage to the cable caused by single - point lifting. It is forbidden to roll or throw the cable reel from a height.
Storage Conditions
Delivery Process
Order Confirmation: After receiving the customer's order, the staff will check the product specifications, quantity, delivery address and other information within 1 working day and confirm the inventory status. For orders with stock, notify the customer in time; for orders that need to be produced, inform the customer of the production cycle.
Stock Preparation and Inspection: Prepare goods according to the order requirements. After stock preparation, inspect the appearance and logo of the cable to ensure that the delivered products meet the order requirements and quality standards.
Delivery Arrangement: In - stock orders are arranged for delivery within 24 hours after confirmation; customized orders are delivered in time after production and passing the inspection. Select a suitable logistics company and determine the transportation method according to the goods and customer requirements.
Logistics Tracking: After delivery, timely inform the customer of logistics information (such as logistics tracking number, contact information of the logistics company, etc.) to facilitate the customer to track the transportation status of the goods. At the same time, the staff will track the transportation of the goods to ensure that the goods are delivered smoothly.
Sample Policy
Sample Provision: Customers can apply for free samples, and the length of the sample is generally 1 meter. The sample includes the complete cable structure (conductor, insulation layer, sheath) and can reflect the material and structure of the product.
Application Process: Customers submit sample applications through official channels (such as official website, customer service phone, etc.), provide relevant information (such as company name, contact information, purpose, etc.), and the staff will arrange delivery after review.
Delivery Method: Samples are delivered by express, and the freight is borne by the customer (if a purchase cooperation is reached later, it can be negotiated to deduct from the payment).
Sample Support: Provide relevant test reports and description materials of the samples. If customers need to test the samples, necessary technical support and guidance can be provided.
Quality Commitment
Problem Handling
Response Time: After the customer reports a product problem, the company's customer service staff will respond within 2 hours to understand the details of the problem.
Solution: Put forward a preliminary solution within 24 hours according to the problem situation. For problems that need on - site inspection, the company will arrange technical personnel to arrive at the site within the agreed time (within 24 hours in adjacent provinces and within 48 hours in remote areas).
Handling Follow - up: During the problem - solving process, timely feedback the progress to the customer. After the problem is solved, conduct a return visit to confirm customer satisfaction.
Additional Services
Technical Support: Provide customers with product selection guidance, and recommend appropriate cable specifications according to the customer's use scenario and power demand. Provide technical consultation and guidance on cable laying and installation, and can send relevant technical materials and videos.
Training Services: For bulk purchase customers, technical personnel can be arranged to conduct on - site training on product use and maintenance.
Regular Return Visits: Regularly visit customers to understand the product use situation, collect customer opinions and suggestions, and continuously improve products and services.
Hongtai Cable Technology Co., Ltd
E-mail: export@qlcables.com
sales@qlcables.com
Tel/whatsapp:+86-18032066271
Tambahkan : Zona Pengembangan Industri Xiaokou, Kabupaten Ningjin, Kota Xingtai , Provinsi Hebei, Cina
Hak Cipta © Hongtai Cable Technology Co., Ltd Dukungan Teknis:Teknologi Ronglida
Situs web ini menggunakan cookie untuk memastikan Anda mendapatkan pengalaman terbaik di situs web kami.