Documentation: 1.5/2.5/4/6 mm² Single Core Copper Conductor PVC Insulated Electrical Wire

1. Product-Specific Details

The 1.5/2.5/4/6 mm² single Core Copper conductor PVC Insulated Electrical Wire is a highly versatile, CE-certified solution engineered for low-voltage power distribution (450/750V) in residential, commercial, and light industrial settings. Its design prioritizes safety, efficiency, and adaptability to diverse wiring scenarios, with core attributes tailored to meet global electrical standards and on-site construction needs.

1.1 Core Specifications

All dimensions, electrical performance, and material parameters adhere to IEC 60228 (conductors) and IEC 60245-1 (PVC Insulated Cables), ensuring consistency and compatibility across markets. The table below details key specifications by cross-sectional area:


Parameter1.5mm²2.5mm²4mm²6mm²
Conductor Details- Purity: ≥99.95% electrolytic copper
- Structure: Single-core solid
- Diameter: ~1.38mm (±0.02mm)
- Purity: ≥99.95% electrolytic copper
- Structure: Single-core solid
- Diameter: ~1.78mm (±0.02mm)
- Purity: ≥99.95% electrolytic copper
- Structure: Single-core solid
- Diameter: ~2.25mm (±0.02mm)
- Purity: ≥99.95% electrolytic copper
- Structure: Single-core solid
- Diameter: ~2.76mm (±0.02mm)
Electrical Performance- Rated Voltage: 450/750V (U0/U)
- Resistivity (20℃): ≤0.017241Ω·mm²/m
- Long-term Current-Carrying Capacity (20℃, single-core): ~18A
- Max Load (220V): ~3.96kW
- Rated Voltage: 450/750V (U0/U)
- Resistivity (20℃): ≤0.017241Ω·mm²/m
- Long-term Current-Carrying Capacity (20℃, single-core): ~25A
- Max Load (220V): ~5.5kW
- Rated Voltage: 450/750V (U0/U)
- Resistivity (20℃): ≤0.017241Ω·mm²/m
- Long-term Current-Carrying Capacity (20℃, single-core): ~32A
- Max Load (220V): ~7.04kW
- Rated Voltage: 450/750V (U0/U)
- Resistivity (20℃): ≤0.017241Ω·mm²/m
- Long-term Current-Carrying Capacity (20℃, single-core): ~40A
- Max Load (220V): ~8.8kW
Insulation Parameters- Material: Modified PVC
- Thickness: 0.8mm (±0.1mm)
- Long-term Operating Temp: 70℃
- Short-term Overload Temp: 160℃ (5s)
- Flame-Retardant Grade: GB/T 18380.1-2008 Class C
- Oxygen Index: ≥24%
- Material: Modified PVC
- Thickness: 0.9mm (±0.1mm)
- Long-term Operating Temp: 70℃
- Short-term Overload Temp: 160℃ (5s)
- Flame-Retardant Grade: GB/T 18380.1-2008 Class C
- Oxygen Index: ≥24%
- Material: Modified PVC
- Thickness: 1.0mm (±0.1mm)
- Long-term Operating Temp: 70℃
- Short-term Overload Temp: 160℃ (5s)
- Flame-Retardant Grade: GB/T 18380.1-2008 Class C
- Oxygen Index: ≥24%
- Material: Modified PVC
- Thickness: 1.2mm (±0.1mm)
- Long-term Operating Temp: 70℃
- Short-term Overload Temp: 160℃ (5s)
- Flame-Retardant Grade: GB/T 18380.1-2008 Class C
- Oxygen Index: ≥24%
Mechanical Durability- Tensile Strength (Insulation): ≥12MPa
- Elongation at Break (Insulation): ≥150%
- Service Life: ≥20 years
- Tensile Strength (Insulation): ≥12MPa
- Elongation at Break (Insulation): ≥150%
- Service Life: ≥20 years
- Tensile Strength (Insulation): ≥12MPa
- Elongation at Break (Insulation): ≥150%
- Service Life: ≥20 years
- Tensile Strength (Insulation): ≥12MPa
- Elongation at Break (Insulation): ≥150%
- Service Life: ≥20 years


The 450/750V rated voltage is a critical design feature: “450V (U0)” denotes the maximum safe voltage between the conductor and ground/neutral, while “750V (U)” is the voltage between two conductors. This range aligns with 220V single-phase residential supplies and 380V three-phase light commercial systems, with a 20%-30% safety buffer to withstand peak-load voltage fluctuations (e.g., summer use of air conditioners + refrigerators).

1.2 Material Selection

Material quality directly determines the wire’s performance, safety, and longevity. Every component is selected for its ability to withstand residential/commercial environmental stressors (humidity, temperature changes, mechanical wear) and meet global compliance standards.

1.2.1 Conductor: High-Purity Electrolytic Copper

The single-core solid conductor is crafted from ≥99.95% high-purity electrolytic copper—a material chosen for three unrivaled advantages:


  • Minimal Transmission Loss: Low resistivity (≤0.017241Ω·mm²/m at 20℃) ensures efficient current flow, reducing energy waste and heat generation. For homeowners, this translates to lower electricity bills; for contractors, it eliminates overheating-related insulation aging (a leading cause of short circuits).

  • Mechanical Rigidity: The solid structure (vs. stranded copper) enhances stability during installation—electricians can easily route the wire through wall cavities, PVC/metal conduits, or junction boxes without risk of conductor breakage.

  • Corrosion Resistance: High purity minimizes oxidation, even in humid spaces (e.g., bathrooms, basements), ensuring consistent conductivity over decades.

1.2.2 Insulation: Modified PVC

The insulation layer uses modified polyvinyl chloride (PVC) optimized for residential and commercial use, with properties engineered to address real-world hazards:


  • Flame Retardancy: Compliant with GB/T 18380.1-2008 Class C, the insulation self-extinguishes within 60 seconds in vertical combustion tests and produces no molten drips. This prevents flame spread along wires—critical for kitchens (grease risks) and bedrooms (flammable bedding).

  • Moisture Barrier: With a volume resistivity of ≥1×10¹²Ω・cm and dielectric loss tangent (50Hz) ≤0.08, the insulation blocks moisture penetration. It remains effective in humid environments (e.g., bathrooms with hot showers), eliminating electric leakage risks.

  • Temperature Tolerance: Long-term operation at 70℃ matches the heat output of common devices (e.g., microwaves, computers). For short-term overloads (e.g., temporary surges from power tools), it withstands 160℃ for 5 seconds without cracking or hardening.

  • Smooth Surface: A polished outer layer reduces friction during conduit installation, cutting labor time by 15%-20% compared to rough-insulation wires.

1.3 Targeted Applications

The wire’s four cross-sectional sizes cover nearly all Low-voltage wiring needs in residential and light commercial projects, with clear use-case differentiation to avoid overload:


Cross-Sectional AreaPrimary Applications
1.5mm²- Low-power residential circuits: Bedroom wall lamps, hallway lighting, phone chargers, small fans
- Secondary uses: Doorbell wiring, smart home sensor power supplies
2.5mm²- Medium-power residential/commercial circuits: Living room sockets (TV, speaker systems), kitchen blenders/toasters, office desk lamps, small POS machines
- Core use: Main lighting loops in apartments
4mm²- High-power residential circuits: Kitchen ovens, bathroom water heaters (≤8000W), washing machines
- Commercial use: Café espresso machines, small vending machines
6mm²- Heavy-load circuits: Whole-house main incoming wires, 2-3 匹 (2-3HP) wall-mounted air conditioners, commercial refrigerators (≤1000L)
- Special use: Temporary power for small construction tools


Application Limitations: Not suitable for industrial machinery (e.g., 3-phase motors >10kW) or outdoor underground wiring (use Armored Cables for burial).

1.4 Production Process & Quality Control

To ensure consistency, every wire undergoes a 7-step manufacturing process with rigorous testing at each stage. This process is audited annually by third-party labs (SGS, Intertek) to maintain CE certification.


  1. Raw Material Inspection:
    • Copper rods are tested for purity via atomic absorption spectroscopy (AAS) and conductivity via a digital ohmmeter.

    • PVC pellets are analyzed for RoHS compliance (lead, cadmium, mercury <1000ppm) and flame-retardant properties (oxygen index testing).

  2. Conductor Drawing:
    • Copper rods are drawn through diamond dies to the target diameter (e.g., 1.78mm for 2.5mm²) at 200-250℃.

    • Annealing (heating to 400℃, slow cooling) enhances Flexibility and reduces brittleness.

  3. Insulation Extrusion:
    • A computer-controlled extruder coats the copper conductor with molten modified PVC, maintaining uniform thickness (e.g., 0.9mm for 2.5mm²) via laser diameter monitors.

    • The coated wire is cooled in a 15℃ water bath to solidify the insulation, preventing bubbles or cracks.

  4. Curing:
    • Wires are heated to 80℃ for 2 hours to improve insulation adhesion and thermal resistance.

  5. In-Line Testing:
    • Conductor Resistance: Measured with a micro-ohmmeter (must meet ≤0.017241Ω·mm²/m).

    • Insulation Thickness: Checked via a digital caliper (tolerance ±0.1mm).

    • Voltage Withstand: 1.5kV AC applied for 1 minute—no breakdown (current leakage >5mA) allowed.

  6. Flame & Mechanical Testing (Batch Sampling):
    • 1 sample per 1000m is tested for flame retardancy (GB/T 18380.1-2008 Class C).

    • Tensile/elongation tests verify insulation durability (≥12MPa strength, ≥150% elongation).

  7. Spooling & Labeling:
    • Wires are spooled onto reels and labeled with batch numbers, production dates, and CE marks for traceability.

2. General Product Information

To support seamless procurement, installation, and long-term use, the wire is backed by customer-centric services covering packaging, shipping, sampling, and after-sales support—tailored to the needs of contractors, distributors, and end-users.

2.1 Packaging

Packaging is designed for protection, convenience, and waste reduction, with standard and custom options available.

2.1.1 Standard Packaging

  • Format: 100 meters per reel (cardboard or plastic core).

    • Cardboard reels: Lightweight (≈0.5kg), recyclable, ideal for small orders (1-10 reels).

    • Plastic reels: Durable (PP material), reusable, suitable for bulk storage (≥50 reels).

  • Dimensions:

    • Outer diameter: 30cm; inner diameter: 15cm; width: 10cm (all sizes).

    • Stackable design: Up to 10 reels per pallet (saves warehouse space).

  • Protection:

    • Each reel is wrapped in 0.1mm thick polyethylene film to block dust, moisture, and UV light.

    • Corrugated cardboard boxes (for 1-5 reels) include foam inserts to prevent impact damage during transit.

  • Labeling:

    • Reel labels include: Product name, cross-sectional area, rated voltage, CE logo, batch number, production date, safety warnings (“Indoor Use Only,” “Do Not Overload”).

    • Shipping cartons add: Recipient address, weight (≈1.8kg/100m for 1.5mm²; ≈3kg/100m for 6mm²), “Fragile” stickers.

2.1.2 Custom Packaging

For bulk orders (≥10,000 meters), custom options are available:


  • Bulk Reels: 500m/1000m per heavy-duty metal reel (for construction sites).

  • Branded Packaging: Custom labels with distributor logos (minimum order: 5000 meters).

  • Palletization: 50 reels per wooden/plastic pallet, secured with stretch film and steel straps (for sea freight).

2.2 Shipping & Logistics

Global shipping is supported via partnerships with leading carriers, with options optimized for order size and destination.

2.2.1 Shipping Methods

Order SizeShipping MethodCarriersDelivery Time (Typical)
Small (1-10 reels)Express CourierDHL, FedEx, UPS2-5 days (international); 1-2 days (domestic)
Medium (11-50 reels)Air FreightTNT, Air China Cargo5-8 days (international); 3-4 days (regional)
Bulk (≥50 reels)Sea Freight (international)
Road Freight (domestic)
Maersk, COSCO (sea); C.H. Robinson (road)20-40 days (sea, Europe/NA); 3-7 days (road, within 500km)

2.2.2 Customs Support

For international orders, we provide full documentation to avoid delays:


  • Required Documents:

    • Commercial Invoice (HS Code: 7326.11.00 for insulated Copper Wires).

    • Packing List (reel quantity, length, weight).

    • CE Certificate of Conformity (signed by our quality manager).

    • MSDS (Material Safety Data Sheet) for PVC/copper.

  • Regulatory Guidance: Pre-shipment advice on country-specific requirements (e.g., UL listing for the U.S., SAA certification for Australia).

2.2.3 Tracking

  • A unique tracking number is sent to customers within 24 hours of shipment (via email/SMS).

  • Real-time updates are available via the carrier’s website (e.g., DHL Track & Trace).

  • For sea freight, weekly updates on container location and ETA (Estimated Time of Arrival) are provided.

2.3 Sample Provision

We offer free samples to qualified customers (contractors, distributors) to verify quality and compatibility before bulk orders.

2.3.1 Sample Details

  • Standard Samples: 1m/5m lengths (all cross-sectional areas, all color codes: red/yellow/green for live, blue for neutral, yellow-green for ground).

  • Custom Samples: 10m minimum for special colors (lead time: 5-7 days).

2.3.2 Request Process

  1. Submit a request via email (samples@wire-supplier.com) or our website, including:

    • Required cross-sectional area/color.

    • Sample length.

    • End-use (e.g., “residential project in Germany”).

    • Delivery address.

  2. Sample approval within 24 hours (standard samples) or 48 hours (custom samples).

  3. Shipping via DHL/FedEx (customer covers courier fee; fee is refunded for bulk orders ≥1000 meters).

2.3.3 Testing Support

  • A “Sample Testing Guide” is provided, outlining how to measure conductor resistance (with a multimeter) and insulation thickness (with calipers).

  • Third-party testing (SGS/Intertek) is covered for bulk orders placed within 30 days of sample receipt.

2.4 After-Sales Service

Our after-sales program ensures long-term support, with a focus on resolving issues quickly and minimizing project delays.

2.4.1 Warranty

  • Coverage: 10-year limited warranty against manufacturing defects, applicable to all cross-sectional sizes of the wire. This warranty covers:

    • Conductor Defects: Issues such as inconsistent diameter (beyond ±0.02mm tolerance), reduced conductivity (resistivity >0.017241Ω·mm²/m at 20℃), or structural breakage caused by faulty drawing/annealing processes.

    • Insulation Defects: Cracking, peeling, or softening of the PVC Insulation under standard operating conditions (≤70℃), as well as electrical insulation failure (e.g., leakage detected during voltage withstand tests) due to substandard extrusion.

    • Certification Non-Compliance: Failure to meet CE standards (e.g., electromagnetic compatibility or flame-retardant performance below GB/T 18380.1-2008 Class C) confirmed by third-party testing.

  • Exclusions: The warranty does not apply to damage caused by:

    • Improper installation (e.g., overloading beyond the rated current-carrying capacity, bending the wire at angles <90° which fractures the conductor, or exposing the wire to outdoor elements without protection).

    • Environmental abuse (e.g., prolonged exposure to temperatures >70℃, chemical corrosion from solvents or oils, or rodent chewing).

    • Unauthorized modification (e.g., stripping insulation beyond the required length for terminal connections, or using the wire for industrial machinery outside its load range).

  • Warranty Claim Process:

    • Replacement: For confirmed manufacturing defects, we ship replacement reels within 2-3 business days (free of charge, including courier fees for international orders). The defective reels must be returned to us (we cover return shipping costs) for further analysis.

    • Refund: If the defect causes project delays and replacements are no longer feasible, we process a full refund (including the original shipping cost) within 7 business days of receiving the returned defective products.

    • On-Site Remediation: For critical projects (e.g., a residential complex under construction), our engineers provide on-site support to resolve installation-related issues caused by product defects (e.g., re-wiring a section with faulty insulation) at no additional cost.

    • Order number and batch number (from the reel label).

    • Detailed description of the defect (e.g., “2.5mm² wire insulation cracked after 6 months of use in a bedroom socket”).

    • Photographs/videos of the defect (clear shots of the affected area, batch label, and installation environment).

    • Proof of purchase (invoice or delivery receipt).

    1. Claim Submission: Customers must submit a claim via email (aftersales@wire-supplier.com) or our online portal within 15 days of discovering the defect. The submission must include:

    2. Assessment: Our quality team reviews the claim within 48 hours. For minor defects (e.g., 1-2 faulty reels in a 50-reel order), we may request a 10cm sample of the defective wire to verify the issue in our lab. For major defects (e.g., an entire batch with insulation thickness below standard), we dispatch a technical engineer to the customer’s site (for domestic orders) or coordinate with a local partner (for international orders) for on-site inspection—typically within 3-5 business days.

    3. Resolution: Based on the assessment, we offer one of the following solutions:

2.4.2 Technical Support

We provide ongoing technical assistance to help customers use the wire safely and efficiently, regardless of project size:


  • Technical Documentation: Every order includes a digital “Installation & Maintenance Manual” (available in English, Spanish, German, and Mandarin) covering:

    • Step-by-step wiring guidelines (e.g., how to strip insulation without damaging the conductor, proper connection to copper terminal blocks, and routing through PVC/metal conduits).

    • Load calculation charts (e.g., “How many 100W bulbs can a 1.5mm² wire support?” or “Maximum number of sockets per 4mm² circuit”).

    • Troubleshooting tips (e.g., identifying leakage via a multimeter, resolving overheating issues, and testing for conductor continuity).

  • 24/7 Technical Hotline: For urgent issues (e.g., suspected leakage during installation or unexpected insulation damage), customers can call our toll-free hotline (+XX-XXX-XXXXXXX) or use the live chat feature on our website. Our team of certified electrical engineers provides real-time advice—typically resolving 80% of queries within 15 minutes. For complex issues (e.g., compatibility with smart home systems), we schedule a follow-up video call within 1 hour.

  • On-Site Training: For bulk customers (e.g., construction firms or electrical contractors ordering ≥50,000 meters), we offer free on-site training sessions. These sessions (2-3 hours) cover:

    • Wire identification (distinguishing between cross-sectional sizes via diameter and color coding).

    • Compliance with local building codes (e.g., NEC 2023 for the U.S., IEC 60364 for the EU, and GB 50303 for China).

    • Safety best practices (e.g., avoiding overload, testing insulation before energizing, and handling damaged wires).

2.4.3 Feedback and Continuous Improvement

We actively solicit customer feedback to enhance product quality and service, ensuring the wire remains aligned with evolving market needs:


  • Post-Delivery Surveys: 10 days after order completion, customers receive a short online survey (5-7 questions) via email. The survey focuses on:

    • Product performance (e.g., “Did the wire meet your expectations for flexibility during installation?”).

    • Shipping experience (e.g., “Was the order delivered on time and in good condition?”).

    • Service satisfaction (e.g., “Was the technical support team helpful?”).
      Responses are analyzed monthly, and scores are tracked in a “Customer Satisfaction Dashboard” (shared with the product development and logistics teams).

  • Defect Root-Cause Analysis: All defective wires returned under warranty undergo a detailed lab analysis to identify the root cause (e.g., a machinery error during extrusion or contaminated PVC pellets). Results are used to update manufacturing processes—for example, if a batch of 4mm² wire is found to have inconsistent insulation thickness, we recalibrate the extrusion machine’s laser diameter monitor and add an extra inspection step for that size.

  • Customer Advisory Board: We invite 10-15 key customers (e.g., leading electrical distributors in Europe, North America, and Southeast Asia) to join our annual Customer Advisory Board (CAB) meeting. The CAB provides input on:

    • Emerging needs (e.g., “We require a 6mm² wire with higher flame retardancy for high-rise buildings”).

    • Service improvements (e.g., “Faster customs clearance support for shipments to the Middle East”).

    • New product ideas (e.g., “A UV-resistant version for covered outdoor patios”).
      Feedback from the CAB directly informs our 12-month product development plan—for instance, based on 2023 CAB input, we launched a modified 2.5mm² wire with thicker insulation (1.0mm vs. 0.9mm) for high-humidity regions like Southeast Asia.

3. Compliance and Certification Summary

To ensure global market access and customer confidence, the 1.5/2.5/4/6 mm² single core copper conductor PVC Insulated Wire meets strict international standards and holds key certifications:


  • CE Certification: Complies with the EU Low Voltage Directive (2014/35/EU) and IEC 60245-1. This certification confirms the wire meets European requirements for electrical safety (e.g., voltage withstand, insulation resistance), mechanical performance (e.g., tensile strength), and electromagnetic compatibility (EMC)—no additional testing is needed for sale or use in EU member states, Norway, Switzerland, or Turkey.

  • RoHS Compliance: Meets RoHS 2.0 (Directive 2011/65/EU) restrictions on hazardous substances. Testing confirms lead (Pb) <1000ppm, cadmium (Cd) <100ppm, mercury (Hg) <1000ppm, hexavalent chromium (CrVI) <1000ppm, polybrominated biphenyls (PBBs) <1000ppm, and polybrominated diphenyl ethers (PBDEs) <1000ppm—making the wire safe for use in residential spaces (e.g., children’s rooms) and commercial offices with strict environmental standards.

  • National Standards Compliance:

    • China: GB/T 5023.1 (PVC Insulated Cables for low voltage) and GB/T 18380.1-2008 (flame retardancy).

    • U.S.: Compatible with NEC 2023 (National Electrical Code) for indoor residential wiring (when paired with UL-listed accessories).

    • Australia: Meets AS/NZS 3000 (wiring rules) for low-voltage installations (requires SAA certification for formal market access, which we can arrange upon request).

4. Conclusion

The 1.5/2.5/4/6 mm² single core copper conductor PVC insulated electrical wire is a technically advanced, customer-focused solution for low-voltage power distribution. Its modular cross-sectional design covers all key residential and light commercial needs—from small lighting circuits (1.5mm²) to heavy-load main lines (6mm²)—while high-purity copper and modified PVC ensure safety, efficiency, and a 20-year service life.


Complementing its technical strengths is a comprehensive support system: practical 100m reel packaging (reducing waste), global shipping with customs assistance (ensuring on-time delivery), free samples (enabling pre-purchase verification), and a 10-year warranty backed by 24/7 technical support (minimizing project risks). CE and RoHS certifications further ensure compliance with global standards, making the wire a reliable choice for both domestic and international projects.


For home improvement electricians, building contractors, or procurement teams seeking a versatile, safe, and cost-effective wiring solution, this wire delivers consistent performance and peace of mind—from installation to long-term use.
Pelajari lebih lanjut tentang produk kabel
Hubungi Hongtai Cable Technology Co., Ltd
Hubungi kami

Hongtai Cable Technology Co., Ltd

E-mail: export@qlcables.com

           sales@qlcables.com

Tel/whatsapp:+86-18032066271

Tambahkan : Zona Pengembangan Industri Xiaokou, Kabupaten Ningjin, Kota Xingtai , Provinsi Hebei, Cina

Hak Cipta © Hongtai Cable Technology Co., Ltd  Dukungan Teknis:Teknologi Ronglida


Peta situs

Situs web ini menggunakan cookie untuk memastikan Anda mendapatkan pengalaman terbaik di situs web kami.

Menerima menolak